Portable electric balers operating indicator shows

Source:本站原创    Posttime:2014-7-23 15:07:59
The operational status of the machine Indicator Status Notes
Load cell
(Or disable the machine 5 minutes)
the green light goes out Into the power-saving mode, the electrical system is shut down. (When the machine out 5 minutes later, will enter power-saving mode, For resume operation, follow these steps: must first be closed with a button to restore the electrical system, and then close with a button to tighten strapping tape before bond can be cut action, if no action to restore the electrical system and tightening up on the direct bond movements, then the hand-held electric packer will not move.)
Press the button with a hand-held electric balers income The light is green Said electrical system and the normal (please wait a second, this is the internal circuitry automatically detect the time)
And then closed with a hand-held electric balers press the button to tighten the strapping tape The light is green When set to tie up power, portable power pack will automatically stop, does not meet the set before the tie strength can be interrupted at any time to tighten the operation and start again.
Adhesive knob will pull forward to the "start" position, to cut off the bond The light is green Please refer to the 5.4 bonded strapping tape
Bonded cut off the machine automatically bonding surface cooling Green lights flashing Do not stop at the green light flashes before the adhesive knob backwards regain "off" position, so as to avoid the efficiency of the reduction or bonding surface bonded to open collapse.
Cooling completed Portable electric balers green light to stop flashing and return to normal The same time, their calls will be "Bee ..." remind you that the cooling action has been completed
Tighten the bond can not operate Red lights flashing Means that the power has been exhausted, please charge the battery at this time, there will be a reminder of the call and sound of "Bee ... Bee ... Bee ..." continued tweet, you must disconnect the battery, their calls will stop